Showing results: 256 - 270 of 346 items found.

  • Cable and Harness Tester

    CHT - Get Control, Inc.

    The Cable and Harness Tester (CHT) provides multiple testing capabilities for up to 300 connector/harness test points. Test capabilities include DC Insulation Resistance (IR), DC and AC Dielectric Withstanding Voltage (DWV), and 2-Wire and 4-Wire Continuity.

  • Digital (1kV up) H.V. Insulation Tester

    6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.

  • Digital (1kV up) H.V. Insulation Testers

    6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.

  • Analog Insulation Tester - Manual Ranging Insulation Tester with 250V, 500V, and 1000V Test Voltages

    380320 - Extech Instruments Corporation

    The 380320 is an Analog Insulation Tester with a large, easy to read analog display. Featuring a live circuit warning which displays the actual AC voltage measurement, Automatic discharge circuit, Lock Power On feature for extended test times, and Insulation resistance up to 400MΩ. Complete with heavy duty test leads, alligator clip test lead, 6 x AA batteries, hanging strap and hard carrying case.

  • Multifunction Instrument

    COMBI521EV - HT Italia Srl

    COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

  • Digital High Voltage Breakdown Testers (HV Tester)

    Premier Electrosystems

    The typical use of high voltage testing is to confirm performance. The high voltage tests are included in type and routine tests to meet the required IS standards, quality and reliability. Some of them are insulation resistance tests, dielectric type tests, lightning and switching impulse tests, partial discharge measurement, etc. Premier's high voltage tester checks the insulation between line to earth, neutral to earth, primary to earth, secondary to earth and between primary & secondary.

  • Relaying Current Transformer Analyser

    Eltel Industries

    *Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.

  • Electrical Circuits Control Device

    ZET 452 - ZETLAB Company

    ZET 452 is an automated module for electrical circuits parameters control that is used for electrical circuits impedance and insulation resistance monitoring in automated mode. The monitoring is performed in accordance with the set participation and without participation of an operator. ZET 452 allows to reduce the time necessary for verification procedure more than in 20 times if compared with the standard measurement instruments normally used for these purposes.

  • Test Phone

    DR-700 - Daerim Electronics Co.

    1. Insulation resistance measurement(earth-state, line-cut, line-short, and telephone capacity measuring) 2. Tone & pulse dialing3. Speakerphone for hands free two way conversation4. Subscriber calling5. Last number redial6. Hook and flash function7. High impedance monitor function8. Transmitter mute switch9. Continuous polarity LED indications10. Line powered with high voltage protection11. Water-proof

  • Electrical Safety Analyzer

    19032 - Chroma Systems Solutions, Inc.

    Our Electrical Safety Analyzers combine Hipot, Insulation Resistance ( IR), Ground Bond (GB), Leakage Current (LC)/AC LC/DC LC, and Dynamic Function Tests. Savings can be up to 50% of production line space by not having to purchase and rack several safety test instruments. It also increases efficiencies of electrical safety testing and reduces associated labor costs.

  • Insulation Tester

    Tenmars Electronics Co., Ltd.

    *3-1/2 digit LCD display with maximum reading of 2000.*Overload indication.*Low battery indication.*Measures high insulation resistance manual range: 0.1MΩ to 2000MΩ*250V: 0.1MΩ to 200MΩ.*500V: 0.1MΩ to 200MΩ.*1000V: 1MΩ to 2000MΩ.*Measures AC 0 to 750V and DC voltages 0V to 1000V.*Function Keys: Data Hold, Max.*Continuity Test.

  • Surge Arrester Testing

    Weshine Electric Manufacturing Co., Ltd

    This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.

  • Ground Earth Resistance Tester

    2678X - Shenzhen Chuangxin Instruments Co., Ltd.

    Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.

  • Electrical Safety Multi-Analyzer

    TOS9300 Series - Kikusui Electronics Corp.

    The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

  • Compression Test Apparatus

    CT-20 C - Lumetronics

    Is designed to perform tests specified in many standards where resistance of insulating materials to elevated operating temperatures is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaires, motors, connectors, etc. The test ensures that external parts of insulating material, the deterioration of which might cause the appliance to fail to comply with the relevant standards, are sufficiently resistant to heat